EQ-ULTRASOUND
Low frequency ultrasound
EQ-ULTRASOUND is a device aimed at treating muscle, joint, ligament and tendon pathologies in the equines and small animals.
What sets the 38 KHz low-frequency generator apart is its ability to produce both a diathermic and cavitation effect, stimulating the tissues deeper than the 1/3 MHz ultrasounds.
Therapeutic indications
- Arthropathies: Arthritis, Arthrosis, Adhesive Capsulitis
- Calcifications: Muscular, Tendineous, Osteophytes
- Myofascial pains: Trigger Points, Tender Points
- Tendinopathy: Bursitis, Fasciitis, Tendinitis, Tendinosis
- Pulled muscle: Elongations, Contractures, Fibrosis
- Pulled TLH: Tendons, Ligaments, Haematomas
BENEFITS
- Improvement in joint mobility
- Increased tendons and ligaments flexibility
- Muscle and joint pain reduction (antalgic action)
- Treatments of scars
ACCESSORIES
PULSED FLAT
Diam. 50 mm
Pulsed wave
Defocused beam
Mechanism of action:
Ultrasound transducer with defocused emission, suitable for the treatment of muscle tissues in the acute and subacute phase
Suitable for:
Arthropathies: Arthritis
Tendinopathy: Bursitis, Tendinitis
Pulled muscle: Elongations, Contractures
Pulled TLH: Tendons, Ligaments, Haematomas
PULSED CONCAVE
Diam. 50 mm
Pulsed wave
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in the acute and subacute phase
Suitable for:
Arthropathies: Arthrosis
Tendinopathy: Fasciitis, Tendinosis
Pulled muscle: Contractures, Fibrosis
Pulled TLH: Tendons, Ligaments, Haematomas
CONTINUOUS FLAT
Diam. 50 mm
Continuous wawe
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in chronic phase
Suitable for:
Calcifications: Osteophytes.
Pulled muscle: Fibrosis
CONTINUOUS CONCAVE
Diam. 50 mm
Continuous wawe
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in chronic phase.
Suitable for:
Calcifications: Osteophytes
Pulled muscle: Fibrosis
CONVEX TRIGGER
Diam. 18 mm
Pulsed wawe
Defocused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in chronic phase
Suitable for:
Arthropathies: Adhesive Capsulitis
Calcifications: Muscular, Tendineous
Myofascial pains: Trigger Points, Tender Points
CONCAVE TRIGGER
Diam. 22 mm
Pulsed wawe
Defocused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of trigger points in chronic phase
Suitable for:
Arthropathies: Adhesive Capsulitis
Calcifications: Osteophytes
Myofascial pains: Trigger Points, Tender Points
MICRO SHOCK WAVE
Diam. 33 mm
Pulsed wave
Radial beam
Mechanism of action:
Ultrasound transducer with radial emission, indicated for the treatment of fibrosis in the sub-acute and chronic phase.
Suitable for:
Arthropathies: Arthrosis.
Calcifications: Muscular, Tendineous.
Tendinopathy: Fasciitis, Tendinitis, Tendinosis.
Pulled muscle: Fibrosis.