EQ-SPORT
Ultrasound device for massage (non-therapeutic purposes) for the sports and wellness sector
EQ-SPORT uses the physics of electrical signals that mainly concern the usefulness of heating deep tissues. The device is useful for treatments in the fields of sports medicine, postural rehabilitation, in decontracting massages and treatments in the fields of aesthetics and well-being.
EQ-SPORT is a low-frequency ultrasound device (38 KHz) stimulating the tissues deeper than the 1/3 MHz ultrasounds.
Coadjuvant in:
• recovery of muscle tone
• recovery from muscle contracture
• reabsorption of oedema due to overuse injuries
• tissue stimulation in the aesthetic and wellness sectors
ACCESSORIES
PULSED FLAT
Diam. 50 mm
Pulsed wave
Defocused beam
Mechanism of action:
Ultrasound transducer with defocused emission, suitable for the treatment of muscle tissues in the acute and subacute phase.
Suitable for:
Arthropathies: Arthritis
Tendinopathy: Bursitis, Tendinitis
Pulled muscle: Elongations, Contractures
Pulled TLH: Tendons, Ligaments, Haematomas
Dermathology: Lymphoedemas
PULSED CONCAVE
Diam. 50 mm
Pulsed wave
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in the acute and subacute phase.
Suitable for:
Arthropathies: Arthrosis
Tendinopathy: Fasciitis, Tendinosis
Pulled muscle: Contractures, Fibrosis
Pulled TLH: Tendons, Ligaments, Haematomas
Dermathology: Lipedemas
CONTINUOUS FLAT
Diam. 50 mm
Continuous wave
Defocused beam
Mechanism of action:
Ultrasound transducer with defocused emission, suitable for the treatment of muscle tissues in the chronic phase
Suitable for:
Calcifications: Muscular, Tendineous
Pulled muscle: Fibrosis
Dermathology: Lymphoedemas
CONTINUOUS CONCAVE
Diam. 50 mm
Continuous wave
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of tendons and joints in chronic phase
Suitable for:
Calcifications: Osteophytes
Pulled muscle: Fibrosis
Dermathology: Lipedemas
CONVEX TRIGGER
Diam. 18 mm
Pulsed wave
Defocused beam
Mechanism of action:
Ultrasound transducer with defocused emission, suitable for the treatment of trigger points in the acute and subacute phase.
Suitable for:
Arthropathies: Adhesive Capsulitis
Calcifications: Muscular, Tendineous
Myofascial pains: Trigger Points, Tender Points
CONCAVE TRIGGER
Diam. 22 mm
Pulsed wave
Focused beam
Mechanism of action:
Ultrasound transducer with focused emission, suitable for the treatment of trigger points in chronic phase.
Suitable for:
Arthropathies: Adhesive Capsulitis
Calcifications: Osteophytes
Myofascial pains: Trigger Points, Tender Points